Por favor, use este identificador para citar o enlazar este ítem: http://dspace.espoch.edu.ec/handle/123456789/8365
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorGonzález López, Nadia Aimee-
dc.contributor.authorParra Riofrío, Katherine Michael-
dc.date.accessioned2018-06-19T13:04:29Z-
dc.date.available2018-06-19T13:04:29Z-
dc.date.issued2018-03-
dc.identifier.citationParra Riofrío, Katherine Michael. (2018). Determinación de dosis en la superficie de entrada recibida por pacientes sometidos a procedimientos intervencionistas en la Unidad de Hemodinámica del Hospital Carlos Andrade Marín. Escuela Superior Politécnica de Chimborazo. Riobamba.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/8365-
dc.descriptionEl objetivo de trabajo fue estimar la Dosis en la Superficie de Entrada recibida por pacientes sometidos a procedimientos intervencionistas: Cinecoronariografía, Cateterismo e Intervencionismo Percutáneo Coronario en la Unidad de Hemodinámica del Hospital Carlos Andrade Marín de Quito en el periodo de Septiembre 2017 a Enero 2018. Para ello se utilizaron dosímetros termoluminiscentes proporcionados y analizados por el departamento de dosimetría del Hospital Carlos Andrade Marín, ubicados en la región posterior de la cavidad torácica dentro del campo radiante. Los pacientes seleccionados para dicho trabajo fueron clasificados bajo criterios médicos y sus características físicas: talla y peso. Los resultados muestran que los valores de estimación de dosis en superficie de entrada obtenidas no superaron en ningún caso los valoreslímites recomendados internacionalmente por el Organismo Internacional de Energía Atómica (OIEA) para la aparición de efectos determinísticos en piel (menor 2 Gy). Estos valores de estimación Dosis en Superficie de Entrada se sugieren que sean considerados y analizados por el departamento de protección radiológica del Hospital Carlos Andrade Marín como niveles de referencia para la unidad de Hemodinámica.es_ES
dc.description.abstractThis present investigation objective is to estimate the Entrance Surface Dose received by patients who have had interventional procedures as coronary angiography, Catheterization, and Percutaneous Coronary Intervention at Carlos Andrade Marín Hospital in Quito from September 2017 to January 2018. We used thermoluminescence dosimeters provided and analyzed by the Dosimetry Department. They were located on the posterior chest cavity region inside of the radiation field. The patients selected for this investigation were classified according to medical criteria and their physical characteristics such as: height and weight. The results show that the entrance surface dose appreciation values do not exceed the limit values recommended by The International Atomic Energy Agency (IAEA) for the deterministic effect appearance in skin (less 2Gy). These appreciation values Entrance Surface Dose must be considered and analyzed by the Office of Radiation Protection of this Hospital as reference levels for the Hemodynamics unit.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDCTFC;86T00056-
dc.subjectBIOFÍSICAes_ES
dc.subjectPROTECCIÓN RADIOLÓGICAes_ES
dc.subjectCARDIOLOGÍA INTERVENCIONISTAes_ES
dc.subjectDOSIS EN LA SUPERFICIE DE ENTRADAes_ES
dc.subjectDOSÍMETROS TERMOLUMINISCENTESes_ES
dc.subjectEFECTOS DETERMINISTICOSes_ES
dc.subjectAFECCIONES A LA PIELes_ES
dc.titleDeterminación de dosis en la superficie de entrada recibida por pacientes sometidos a procedimientos intervencionistas en la Unidad de Hemodinámica del Hospital Carlos Andrade Marín.es_ES
dc.typebachelorThesises_ES
dc.contributor.miembrotribunalYanchapanta, Vilma Nohemí-
Aparece en las colecciones: Biofísica

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
86T00056.pdf2,95 MBAdobe PDFVista previa
Visualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.