Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.advisor | Pachacama Choca, Richard Williams | - |
dc.contributor.author | Delgado Brito, Marlon Santiago | - |
dc.date.accessioned | 2018-06-18T20:27:45Z | - |
dc.date.available | 2018-06-18T20:27:45Z | - |
dc.date.issued | 2018-02 | - |
dc.identifier.citation | Delgado Brito, Marlon Santiago. (2018). Implementación de un protocolo de control de calidad del equipo de rayos X TITAN-2000M para el Hospital General Provincial Docente Riobamba. Escuela Superior Politécnica de Chimborazo. Riobamba. | es_ES |
dc.identifier.uri | http://dspace.espoch.edu.ec/handle/123456789/8362 | - |
dc.description | El objetivo de este trabajo de titulación fue diseñar e implementar un protocolo de control de calidad para el equipo de rayos X en el área de Imagenología del Hospital General Provincial Docente Riobamba. Para ello se describió el principio físico de funcionamiento del equipo,la composición mecánica y eléctrica del mismo detallando la capacidad funcional, producción y restricciones de uso. La caracterización del protocolo se obtuvo basándose en el método deductivo con el cual se realizó las pruebas. Cada examen realizado al equipo fue controlado por un rango de tolerancia del 10% impuesto por el organismo regulador. Las pruebas implementadas en el equipo radiográfico aportan información técnica que ayuda a cumplir con los estándares de calidad fijados por la Subsecretaria de Control y Aplicaciones Nucleares. Este protocolo presenta información del funcionamiento eléctrico y mecánico, con ello el Personal Ocupacionalmente Expuesto (POE) evalúa el nivel de eficiencia del equipo, al mismo tiempo se controla la radiación existente en el área de Imagen, para esto se realizó análisis dosimétricos que evalúan el nivel existente de protección radiológica. Para obtener una mejor precisión aproximadamente 5% en la medición del Kilovoltaje se usó un miliamperaje entre 10 y 50 mA. El ajuste del Control Automático de Exposición proporcionó imágenes sobre una no uniformidad del campo de radiación. El voltaje de operación presenta un error aproximado de 8.4%.Mediante una ponderación de la tasa de dosis se demostró que el POE absorbe una dosis anual de 8.71 miliSievers. El área de Imagen deberá contar con un inspector de seguridad radiológica para evitar accidentes, mantener actualizado el protocolo y mantener la seguridad del POE. | es_ES |
dc.description.abstract | The objective of this degree work was to design and implement a quality control protocol to the Xray equipment in the area of Imaging from Hospital General Provincial Docente Riobamba. Therefore, the physical principle of the equipment's operation was described, as well as its mechanical and electrical composition detailing the functional capacity, production and use restrictions. The characterization of the protocol was obtained based on the deductive method with which the tests were carried out. A 10% tolerance range imposed by the regulatory body controlled each test performed on the equipment. The tests implemented in the radiographic equipment provide technical information that helps to fulfill with the quality standards set by the Undersecretary of Control and Nuclear Applications. This protocol presents information on the electrical and mechanical functioning, with this the Occupationally Exposed Personnel (OEP) evaluates the level of efficiency of the equipment, at the same time the existing radiation in the image area is controlled, hence this dosimetry analysis was carried out to evaluate the existing level of radiation protection. To obtain a better precision approximately 5% in the kilovoltage measurement a milliamperage between 10 and 50 mA was used. The adjustment of the Automatic Exposure Control provided images about nonuniformity of the radiation field. The operating voltage presents an error of approximately 8.4%. Through a weighting of the dose rate it was found that the OEP absorbs an annual dose of 8.71 milliSievers. The image area must have a radiological safety inspector to prevent accidents, keep the protocol updated and maintain the safety of the OEP. | es_ES |
dc.language.iso | spa | es_ES |
dc.publisher | Escuela Superior Politécnica de Chimborazo | es_ES |
dc.relation.ispartofseries | UDCTFC;86T00053 | - |
dc.subject | BIOFÍSICA | es_ES |
dc.subject | RADIOLOGÍA | es_ES |
dc.subject | CONTROL DE CALIDAD | es_ES |
dc.subject | DETECTOR DE RADIACIÓN | es_ES |
dc.subject | DOSIS ABSORBIDA | es_ES |
dc.subject | PROTECCIÓN RADIOLÓGICA | es_ES |
dc.subject | PERSONAL OCUPACIONALMENTE EXPUESTO (POE) | es_ES |
dc.title | Implementación de un protocolo de control de calidad del equipo de rayos X TITAN-2000M para el Hospital General Provincial Docente Riobamba. | es_ES |
dc.type | bachelorThesis | es_ES |