Por favor, use este identificador para citar o enlazar este ítem: http://dspace.espoch.edu.ec/handle/123456789/17268
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorHernández Dávila, Eduardo Segundo-
dc.contributor.authorTorres Piñas, Joseph Daniel-
dc.contributor.authorViera Molina, Richard Manuel-
dc.date.accessioned2022-10-03T22:29:42Z-
dc.date.available2022-10-03T22:29:42Z-
dc.date.issued2022-06-10-
dc.identifier.citationTorres Piñas, Joseph Daniel; Viera Molina, Richard Manuel. (2022). Estudio de la variación de la temperatura obtenida mediante termografía infrarroja en función del incremento de la distancia de medición y la resolución de la cámara termográfica infrarroja. Escuela Superior Politécnica de Chimborazo. Riobamba.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/17268-
dc.descriptionEl presente trabajo de integración curricular tuvo como objetivo estudiar la variación de la temperatura obtenida mediante termografía infrarroja en función del incremento de la distancia de medición y la resolución de la cámara termográfica infrarroja, el cual se realizó a través de la recolección y análisis de datos, además de adecuaciones en un banco de pruebas del Laboratorio de Diagnostico Técnico y Eficiencia Energética, adaptando una probeta de mayor conductividad térmica y tamaño, utilizando cámaras termográficas con distintas resoluciones. Se determinaron treinta y seis valores por cada metro hasta completar doce metros de distancia del elemento inspeccionado, se realizó una regresión lineal entre la variable independiente que es la distancia de medición y resolución de la cámara, también la variable dependiente que es la temperatura obtenida mediante termografía infrarroja, para así obtener la ecuación de corrección definitiva, en el cual se verán involucrados factores externos tales como: el viento, la humedad y el calor, que influyeron que la temperatura no se mantenga constante en la medición, para lo cual se realizó un controlador PID que permitió tener una temperatura constante al momento de realizar las pruebas. Se concluyó que el análisis del tamaño de probeta fue establecido con valores de temperatura proporcionados por la cámara termográfica Satir HotFind-VR, donde el coeficiente de variación de 1,21% de la muestra es menor al 30% establecido, es decir, el tamaño de la probeta de aluminio de 50mm x 50mm es aceptada, de tal manera que la temperatura se distribuye homogéneamente en toda su cara. Además, se recomienda realizar mediciones en un lugar cerrado que no permita el paso de la luz, viento y calor, estos factores afectan que los datos varíen de manera brusca, además de utilizar probetas de otro material para probar su conductividad térmica.es_ES
dc.description.abstractThe objective of this curricular integration work was to study the variation of the temperature obtained by infrared thermography as a function of the increase in the measurement distance and the resolution of the infrared thermographic camera. It was carried out through the collection, data analysis and adaptations in a test bench of the Technical Diagnosis and Energy Efficiency Laboratory. Adapting a test tube with greater thermal conductivity and size, using thermographic cameras with different resolutions. Thirty-six values were determined for each meter until completing twelve meters of distance from the inspected element. A linear regression was performed between the independent variable, which is the measurement distance and the camera resolution, as well as the dependent variable, which is the temperature obtained by infrared thermography, in order to obtain the definitive correction equation. External factors such as: wind, humidity and heat will be involved, which influenced the temperature not to remain constant in the measurement. Then, it was carried out a PID controller that allowed to have a constant temperature at the time of testing. It was concluded that the analysis of the size of the test tube was established with temperature values provided by the Satir HotFind-VR thermographic camera, where the coefficient of variation of 1.21% of the sample is less than the established 30%. In other words, the size of the aluminium specimen of 50mm x 50mm is accepted. So the temperature is distributed homogeneously throughout its face. In addition, it is recommended to carry out measurements in a closed place that does not allow to pass light, wind and heat. These factors affect the data to vary abruptly and using test tubes of another material to test its thermal conductivity.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDCTFM;25T00475-
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.subjectTECNOLOGÍA Y CIENCIAS DE LA INGENIERÍAes_ES
dc.subjectTERMOGRAFÍA INFRARROJAes_ES
dc.subjectVARIACIÓN DE TEMPERATURAes_ES
dc.subjectCÁMARA TERMOGRÁFICA INFRARROJAes_ES
dc.subjectBANCO DE PRUEBASes_ES
dc.subjectCONDUCTIVIDAD TÉRMICAes_ES
dc.titleEstudio de la variación de la temperatura obtenida mediante termografía infrarroja en función del incremento de la distancia de medición y la resolución de la cámara termográfica infrarrojaes_ES
dc.typeinfo:eu-repo/semantics/bachelorThesises_ES
dc.contributor.miembrotribunalGarcía Mora, Félix Antonio-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/3.0/ec/es_ES
Aparece en las colecciones: Ingeniero de Mantenimiento; Ingeniero/a en Mantenimiento Industrial

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
25T00475.pdf4,41 MBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons