Por favor, use este identificador para citar o enlazar este ítem: http://dspace.espoch.edu.ec/handle/123456789/11138
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorYaulema Garcés, Fausto Manolo-
dc.contributor.authorCarpio Moreno, Natacha Miroslava-
dc.date.accessioned2019-07-18T20:42:01Z-
dc.date.available2019-07-18T20:42:01Z-
dc.date.issued2019-04-17-
dc.identifier.citationCarpio Moreno, Natacha Miroslava. (2019). Reducción de la materia orgánica disuelta, mediante el peróxido de hidrógeno como tratamiento independiente, después de cada proceso del tratamiento (físico - químico) de aguas industriales provenientes de la actividad petrolera hacia la Empresa PLUSAMBIENTE S.A. Escuela Superior Politécnica de Chimborazo. Orellana.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/11138-
dc.descriptionEl objetivo fue reducir la materia orgánica disuelta, mediante el peróxido de hidrógeno como tratamiento independiente, después de cada proceso del tratamiento (físico-químico) de aguas industriales provenientes de la actividad petrolera hacia la empresa Plusambiente S.A. Se realizó un estudio sobre el impacto del uso de los floculantes y coadyuvantes en aguas industriales, para lo cual se aplicó un diseño experimental de tipo multivariado. La lógica de la investigación fue la siguiente: se efectuó un relevamiento de los parámetros físico - químicos, siempre adecuados en el chequeo de controles ambientales y pautas para la recolección de muestras representativas, mediciones y operaciones de la descarga de las aguas residuales que lleve a resultados coherentes y comparables en todos los análisis de la calidad de agua en la Empresa Plusambiente S.A. Se colocó en cada jarra de 500 ml de agua industrial, así como 5, 10, 15, 20 y 25ml de óxido de calcio CaO respectivamente. Se añadió 10 ml a cada muestra de Al2(SO4)3; se sustrajo el agua clarificada (físico y químicamente), se añadió10 ml de agua a cada muestra, decantando por completo las muestras; se procedió a tomar la alícuota para análisis en laboratorio donde se midieron los parámetros de Conductividad eléctrica, pH, sólidos totales, Demanda Bioquímica de Oxígeno (DBO5) y Demanda Química de oxígeno (DQO); los resultados de las concentraciones correspondientes fueron los siguientes: 60,87% de DBO5 y 62,34% de la DQO. Se concluye que, siguiendo la continuidad de CaO, Al2(SO4)3 y agua cómo agente reductor y oxidante bajan las concentraciones de la materia orgánica, siendo éste método conveniente y aplicable por sus resultados. Se recomienda el uso adecuado de cada reactivo para su respectivo procedimiento en la verificación y control de aguas industriales.es_ES
dc.description.abstractThe objective was to reduce the dissolved organic matter, using hydrogen peroxide as an independent treatment, after each treatment process (physical-chemical) of industrial waters from the oil activity towards the company Plusambiente SASE conducted a study on the impact of the use of flocculants and coadjuvants in industrial waters, for which an experimental multivariate design was applied. The logic of the investigation was as follows; A survey was made of the physical-chemical parameters, always adequate in the check of environmental controls and guidelines for the collection and representative samples, measurements and operations of the discharge of the wastewater that leads to coherent and comparable results in all the analyzes of the water quality in Empresa Plusambiente SA It was placed in each jar of 500 ml of industrial water, as well as 5,10,15,20 and 25 ml of CaO calcium oxide respectively. 10mñ was added to each sample of A12 (SO4) 3, the clarified water was removed ( physically and chemically), 10 ml of water was added to each sample, decanting the samples completely; We proceeded to take the aliquot for the analysis in the laboratory where the parameters of electrical conductivity, pH, total solids, Biochemical Oxygen Demand (BOD5) and Chemical Oxygen Demand (COD) were measured; the results of the corresponding concentrations were the following: 60.87% of BOD5 and 62.34% of the COD. It is concluded that, following the continuity of CaO, A12 (SO4) 3 and water as reducing agent and oxidizer, the concentrations of organic matter decrease, this method being convenient and applicable for its results. It is recommended the adequate use of each reagent for its respective procedure in the verification and control of industrial waters.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDCTFC;236T0440-
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.subjectBIOTECNOLOGÍAes_ES
dc.subjectCALIDAD DE AGUAes_ES
dc.subjectMATERIA ORGÁNICAes_ES
dc.subjectFLOCULANTESes_ES
dc.subjectCOADYUVANTESes_ES
dc.subjectANÁLISIS FÍSICOQUÍMICOes_ES
dc.subjectPRUEBA DE JARRASes_ES
dc.subjectPERÓXIDO DE HIDRÓGENOes_ES
dc.titleReducción de la materia orgánica disuelta, mediante el peróxido de hidrógeno como tratamiento independiente, después de cada proceso del tratamiento (físico - químico) de aguas industriales provenientes de la actividad petrolera hacia la Empresa PLUSAMBIENTE S.A.es_ES
dc.typebachelorThesises_ES
dc.contributor.miembrotribunalLeón Chimbolema, José Gerardo-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/3.0/ec/es_ES
Aparece en las colecciones: Ingeniero/a en Biotecnología Ambiental; Ingeniero/a Ambiental

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
236T0440.pdf2,59 MBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons