dc.identifier.citationGuillén Santillán, Joselin Michelle. (2018). Dosimetría en pacientes marcados con Tc99m que se realizan diagnóstico con spect en patologías de tórax en el Hospital de Especialidades Carlos Andrade Marín IESS-Quito. Escuela Superior Politécnica de Chimborazo. Riobamba.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/9579-
dc.descriptionLa presente investigación tuvo como objetivo, determinar la dosimetría en pacientes que se realizan diagnóstico con Tomografía Computarizada de Fotón Único (SPECT) en estudios torácicos. Para esto se elaboró un procedimiento que determina la dosis absorbida por el órgano fuente y órganos blanco con un radionúclido en los órganos torácicos (corazón y pulmones), utilizando un fantoma antropomorfo. Se utilizó Tc99m como radiotrazador para diagnóstico de patologías torácicas, el cual fue aplicado en el fantoma antropomorfo de igual o similar densidad másica al tejido humano y además, la toma de datos de 10 pacientes por cada uno de los estudios torácicos. Los valores resultantes de las dosis absorbidas por el órgano blanco y órgano fuente fueron comparados con los límites establecidos por la ICRP 60. Los resultados muestran que las dosis absorbidas para el corazón como órgano blanco fue 0,049 ± 0,02 mGy y para pulmones 0,07 ± 0,03 mGy, los cuales se encuentran dentro de los límites establecidos, así también los coeficientes de atenuación para el corazón es de 0,052 ± 0,03 mGy y para pulmones 0,048 ± 0,02 mGy y de 0,054 ± 0,03 mGy para el derecho e izquierdo respectivamente. Mientras que con el método MIRD se obtuvo una dosis de 0,069 ± 0,04 mGy para pulmones y de 0,065 ± 0,03 mGy para el corazón, con lo cual se verifica que existe una diferencia de valores en los pulmones y corazón debido a que el fantoma es un material inerte, por lo que no realiza ninguna función metabólica, lo cual no permite que el radiofármaco sea eliminado del organismo como se da en los pacientes. Se recomienda continuar con estos estudios mediante el uso de herramientas computacionales.es_ES
dc.description.abstractThe purpose of this investigation was to determine the internal dosimetry in patients who were undergone to Single Photon Emision Computer Tomography diagnosis. In order to conduct this procedure, it was necessary to find out the absorved dose by the Source organ and White organs by means of radionuclide in thoracic organs (heart end lungs). The aforementioned data were obtained through an anthropomorphic phantom. A Tc99m radiotracer was used to diagnose thoracic pathologies which was applied to anthropomorphic phantom with similar human-like mass tisue density; for each thoracic study it was reiquired data taking from ten patients. The resulting values from obsorbed dose by source organ and White organs wre compared to established limits by ICRP 60. Once the process was concluded the following results were as follows: White organ (heart) 0.049±0.02mGy, Source organ (lungs) 0.07±0.03mGy, which were under established limits; heart attenuation coefficient 0.052±0.03mGy, right lung attenuation coefficient 0.048±0.02mGy, left lung attenuation coefficient 0.054±0.03mGy. Through MIRD method, the following data were obtained: lungs 0.069±0.04 mGy; heart 0.065±0.03mGy, these results verify that there exists a value difference in the lungs and heart because the phantom is an inert material; threfore, the phantom does not perform any metabolic function which does not allow the radiopharmaceutical being eliminated from the organism as it occurs in patients. It is reccommended to continue withthese studies by means of computing tools use.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDCTFC;86T00071-
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.subjectBIOFÍSICAes_ES
dc.subjectMEDICINA NUCLEARes_ES
dc.subjectTOMOGRAFÍA COMPUTARIZADA DE FOTÓN ÚNICO (SPECT)es_ES
dc.subjectMÉTODO MEDICAL INTERNAL RADIATION DOSE (MIRD)es_ES
dc.subjectMÉTODO DE LOS COEFICIENTES DE ATENUACIÓNes_ES
dc.subjectFANTOMA ANTROPOMORFOes_ES
dc.titleDosimetría en pacientes marcados con Tc99m que se realizan diagnóstico con spect en patologías de tórax en el Hospital de Especialidades Carlos Andrade Marín IESS-Quito.es_ES
dc.typebachelorThesises_ES
dc.contributor.miembrotribunalOrmaza Hugo, Rosa Maricela-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/3.0/ec/es_ES