Por favor, use este identificador para citar o enlazar este ítem:
http://dspace.espoch.edu.ec/handle/123456789/8997
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.advisor | Vallejo Vizhuete, Henry Ernesto | - |
dc.contributor.author | Allauca Cando, Luis Miguel | - |
dc.contributor.author | Rocha Tenorio, Bladimir Enrique | - |
dc.date.accessioned | 2018-10-10T21:10:17Z | - |
dc.date.available | 2018-10-10T21:10:17Z | - |
dc.date.issued | 2017-11 | - |
dc.identifier.citation | Allauca Cando, Luis Miguel; Rocha Tenorio, Bladimir Enrique. (2017). Diseño e implementación de un sistema automatizado para realizar exámenes de retinoscopía empleando visión artificial para el procesamiento de imágenes de la retina. Escuela Superior Politécnica de Chimborazo. Riobamba. | es_ES |
dc.identifier.uri | http://dspace.espoch.edu.ec/handle/123456789/8997 | - |
dc.description | Se diseñó e implementó un sistema automatizado para realizar exámenes de retinoscopía empleando visión artificial para el procesamiento de imágenes de la retina. Se empleó la técnica de observación y experimentación, para identificar las condiciones necesarias que intervienen en la realización del examen de retinoscopía, se estableció un diseño del sistema mecánico, electrónico y de visión artificial para la selección e instalación de los componentes requeridos para la automatización. Se instaló una cámara de video para obtener las imágenes de la retina que son visualizadas en el computador. Para el funcionamiento del sistema automatizado se desarrolló un algoritmo de procesamiento y comparación de imágenes programadas en el software LabVIEW; a través de una conexión con el puerto serial se envía datos desde el computador hacia la tarjeta de desarrollo Arduino Uno, la cual controla los actuadores que son servomotores que direccionan la posición de los lentes y efectúan el movimiento del haz de luz del retinoscopio. Para el cambio automático de lentes se implementó un sistema mecánico adecuado con el propósito de obtener una imagen fija de la retina; se creó una interfaz hombre máquina (HMI), que permite al operador visualizar el proceso del examen en tiempo real. Con la implementación del sistema se determinó el tiempo promedio de la comparación de imágenes, resultando que: ojos sin ametropía se comparan en 162,28 ms, con miopía en 166,02 ms, con hipermetropía en 170,7 ms y con astigmatismo en 174,75 ms, logrando reducir el tiempo promedio empleado para realizar el examen de retinoscopía de 250 a 150 segundos equivalente al 40%. Se concluyó que el tiempo de comparación de las imágenes incrementa en 2,44% mientras mayor sea el daño refractivo. Se recomienda seguir las instrucciones de los autores para garantizar el correcto funcionamiento del sistema. | es_ES |
dc.description.abstract | An automated system was designed and implemented to perform retinoscopy examinations using artificial vision for the processing of retinal images. The technique of observation and experimentation was used to identify the necessary conditions involved in the retinoscopy examination. A mechanical, electronic and artificial vision design was established for the selection and installation of the necessary components for the automation. A video camera was installed to obtain images of the retina that are displayed on the computer. For the operation of the automated system an algorithm of processing and comparison of images programmed in the LabVIEW software was developed; through a connection to the serial port, data is sent from the computer to the Arduino Uno development board, which controls actuators that are servomotors that direct the position of the lenses and effect the movement of the light beam of the retinoscope. For the automatic change of lenses, a suitable mechanical system was implemented in order to obtain a fixed image of the retina; a human machine interface (HMI) was created, which allows the operator to view the examination process in real time. With the implementation of the system the average time of image comparison was determined, with the result that: eyes without ametropia were compared in 162,28 ms, myopia in 166,02 ms, with farsightedness in 170,7 ms and with astigmatism in 174,75 ms, reducing the time taken to perform the retinoscope examination of 250 to 150 seconds equivalent to 40%. It was concluded that the time of comparison of the images increase in 2,44% while the sea was the refractive damage. It is recommended to follow the instructions of the authors to ensure the correct functioning of the system. | es_ES |
dc.language.iso | spa | es_ES |
dc.publisher | Escuela Superior Politécnica de Chimborazo | es_ES |
dc.relation.ispartofseries | UDCTFIYE;108T0235 | - |
dc.subject | TECNOLOGÍA Y CIENCIAS DE LA INGENIERÍA | es_ES |
dc.subject | TECNOLOGÍA DEL CONTROL AUTOMÁTICO | es_ES |
dc.subject | VISIÓN ARTIFICIAL | es_ES |
dc.subject | EVALUACIÓN DE REFRACCIÓN | es_ES |
dc.subject | PROCESAMIENTO DE IMÁGENES | es_ES |
dc.subject | IMAGEN DE RETINA | es_ES |
dc.subject | RETINOSCOPÍA | es_ES |
dc.subject | AUTOMATIZACIÓN DE PROCESOS | es_ES |
dc.title | Diseño e implementación de un sistema automatizado para realizar exámenes de retinoscopía empleando visión artificial para el procesamiento de imágenes de la retina. | es_ES |
dc.type | bachelorThesis | es_ES |
dc.contributor.miembrotribunal | Mejía Peñafiel, Edwin Fernando | - |
Aparece en las colecciones: | Ingeniero en Electrónica, Control y Redes Industriales; Ingeniero/a en Electrónica y Automatización |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
108T0235.pdf | 3,86 MB | Adobe PDF | Visualizar/Abrir |
Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.