Por favor, use este identificador para citar o enlazar este ítem: http://dspace.espoch.edu.ec/handle/123456789/6849
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorCalderón, Hugo-
dc.contributor.authorVega Quispe, Tanya Elizabeth-
dc.date.accessioned2017-07-14T18:33:51Z-
dc.date.available2017-07-14T18:33:51Z-
dc.date.issued2016-06-
dc.identifier.citationVega Quispe, Tanya Elizabeth. (2016) Diseño de un sistema de tratamiento de aguas residuales para el cantón Archidona de la provincia de Napo. Escuela Superior Politécnica de Chimborazo. Riobamba.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/6849-
dc.descriptionSe diseñó una Planta de Tratamiento de aguas residuales para el Cantón Archidona de la Provincia de Napo con la finalidad de disminuir el impacto ambiental que ocasiona el vertido de estas aguas a un cuerpo de agua dulce. Se inspeccionó el lugar de la descarga del agua residual para proceder a la medición de caudales en un periodo de siete días consecutivos, desde las 06h30 am hasta las 18h00 pm, obteniendo un caudal de aforo de 5,81 L/s. Posteriormente se aplicó un muestreo compuesto en tres horarios de 07h00 am, 12h00am y 18h00 pm, obteniendo una muestra representativa del efluente para su caracterización física, química y microbiológica. Los resultados obtenidos de los análisis indicaron valores de: Demanda Química de Oxígeno (DQO) 391,3 mg/L, Demanda Bioquímica de Oxígeno (DBO) 304 mg/L, Aceites y Grasas 37,2 mg/L, Nitrógeno Amoniacal 45,5 mg/L, Tensoactivos 1,8 mg/L, Sólidos Sedimentables 3,16 mg/L, Coliformes Fecales 1X10 6 UFC/100 ml, mismos que están fuera de los límites permisibles de las normas del Texto Unificado de Legislación Ambiental (TULSMA). Con estos parámetros se propuso un Sistema de Tratamiento idóneo para las aguas residuales del Cantón Archidona, que consta de los siguientes componentes: canal de recepción, rejillas, desengrasador, cuatro humedales artificiales de flujo subsuperficial empleando el pasto alemán (Echinochloa polystachya), una canaleta Parshall para la dosificación del Policloruro de Aluminio, sedimentador y finalmente filtración. Con el presente diseño se alcanzó porcentajes de remoción de: DQO 93,18%, DBO 94,85%, Aceites y Grasas 78,5%, Nitrógeno Amoniacal 98,07%, Tensoactivos 70,6%, Sólidos Sedimentables 96,84%, Coliformes Fecales 99,9%, Turbiedad 92,03%, evidenciando de esta manera que el tratamiento empleado es fiable. Esta Planta de Tratamiento de Aguas Residuales deberá ser implementada por el Gobierno Autónomo Descentralizado Municipal de Archidona para evitar la contaminación del rio Misahuallí.es_ES
dc.description.abstractThis research is intended to design a wastewater treatment station for Archidona from Napo province in order to diminish the environmental impact arisen from the direct wastewater discharges into the river Misahuallí. The point of final wastewater discharge was inspected at first for a 7-day consecutive period from 06:30a.m – 18:00p.m in order to measure the wastewater flow which accounts for 5,81 liters. Afterwards, this control covers compound sampling carried out in 3 time-tables corresponding to 07:00a.m, 12:00a.m and 18:00p.m which let to ensure a representative flow sampling for the biological and physical and chemical characterization. The analysis results reflected substance values such as Oxygen Chemical Demand (DQO) 391 mg/L, Oxygen Biochemical Demand (DBO) 304 mg/L, Oils and Greases 37, 2 mg/L, Ammonia Nitrogen 45,5 mg/L, Tensoactive Substances 1,8 mg/L, Sedimentable solid 3,16 mg/L, Fecal Coliform 1X10 6 UFC/100 ml, which are very high and which exceed limits of norms laid down in the unified text from secondary environmental regulations (TULSMA). Thus, the necessity to have an appropriate system for the wastewater treatment in Archidona was real need; therefore the wastewater treatment station of this study proposal was stated from these parameters, it consist of a catchment water conduit, grilles, a degreaser devise, four wetland devises for superficial flow which are like those used for German grass (Echinochloa polystachya), a Parshall canal for the Polychloride of aluminum dosification, sedimentation and finally for filtration. This wastewater treatment station design allows to reach removal levels which were reflected in percentages as follow: DQO 93,18%, DBO 94,85%, Oils and Greases 78,5%, Ammonia Nitrogen 98,07%, Tensoactive Substances 70,6%, Sedimentable solid 96,84%, Fecal Coliform 99,9%, Turbidity 92,03%, which evidence that the treatment purposed from this study proposal is reliable. Therefore it is advisable for the Archidona Municipality to implement this wastewater treatment station to prevent the Misahuallí river pollution.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDCTFC;96T00358-
dc.subjectINGENIERÍA Y TECNOLOGÍA QUÍMICAes_ES
dc.subjectTRATAMENTO DE AGUAS RESIDUALESes_ES
dc.subjectCARACTERIZACIÓN DEL AGUAes_ES
dc.subjectHUMEDAL DE FLUJO SUBSUPERFICIALes_ES
dc.subjectARCHIDONA (CANTÓN)es_ES
dc.subjectNAPO (PROVINCIA)es_ES
dc.titleDiseño de un sistema de tratamiento de aguas residuales para el cantón Archidona de la provincia de Napo.es_ES
dc.typebachelorThesises_ES
dc.contributor.miembrotribunalAndrade, Mónica-
Aparece en las colecciones: Ingeniero/a Químico/a

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
96T00358.pdf4,41 MBAdobe PDFVista previa
Visualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.