Por favor, use este identificador para citar o enlazar este ítem:
http://dspace.espoch.edu.ec/handle/123456789/21389
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.advisor | Baldeón López, Wilson Oswaldo | - |
dc.contributor.author | Patachi Borja, Brayan Andrés | - |
dc.contributor.author | Ramos Saigua, Carlos Agustín | - |
dc.date.accessioned | 2024-06-10T17:10:53Z | - |
dc.date.available | 2024-06-10T17:10:53Z | - |
dc.date.issued | 2022-03-14 | - |
dc.identifier.citation | Patachi Borja, Brayan Andrés; Ramos Saigua, Carlos Agustín. (2022). Control automático de temperatura y humedad relativa del laboratorio de ensayos de ALUVIDGLASS CIA. LTDA. Escuela Superior Politécnica de Chimborazo. Riobamba. | es_ES |
dc.identifier.uri | http://dspace.espoch.edu.ec/handle/123456789/21389 | - |
dc.description | El presente trabajo tuvo como objetivo la implementación de un sistema electrónico y eléctrico para el control automático de temperatura y humedad relativa, con el fin de desarrollar pruebas de control de calidad basado principalmente en una investigación de laboratorio. Para el desarrollo del sistema bajo investigación documental en el área de la automatización industrial y control de calidad se determinaron las principales variables, temperatura y humedad relativa, que posteriormente se monitorearon dentro de un laboratorio de ensayos. El uso de sensores de temperatura y humedad relativa conectados a un PLC a través de lógica programada permitió el control de actuadores. La información adquirida por los diferentes sensores se visualiza en una pantalla OLED, estos datos se muestran y se registran en tiempo real, para posteriormente realizar acciones de control de temperatura y humedad relativa. El mecanismo de actuación está conformado por un sistema de enfriamiento y calentamiento de aire controlado de manera local. Para la fase experimental se implementó el sistema en un laboratorio de ensayos, ubicado en la ciudad de Ambato, obteniendo como resultado la reducción del 50% del tiempo que tarda el laboratorio para enfriar un grado de temperatura sin intervención del sistema con un consumo de energía de 0,746kWh., por lo que se concluye que el sistema de control de temperatura y humedad relativa es eficiente en su consumo energético respecto a su funcionamiento. Se recomienda incorporar métodos de visión artificial para identificar los materiales que se analizan y así determinar los niveles de temperatura en el proceso de control de calidad. | es_ES |
dc.description.abstract | The objective of this work was the implementation of an electronic and electrical system for the automatic control of temperature and relative humidity, in order to develop quality control tests based primarily on laboratory research. For development of the system under documentary research in the field of industrial automation and quality control, the main variables were determined, temperature and relative humidity, which subsequently were monitored within a testing laboratory. The use of temperature and relative humidity sensors connected to a PLC through programmed logic, allowed the control of the actuators. The information gathered by the different sensors is displayed on an OLED screen, this data is displayed and recorded in real time, to later perform temperature and relative humidity control actions. The mechanism of action is made up of a locally controlled air cooling and heating system. For the experimental phase, the system was implemented in a testing laboratory, which is in the city of Ambato, obtaining as a result the reduction of 50% of the time that the laboratory takes to cool one degree of temperature without intervention of the system with an energy consumption of 0.746kWh., so it is concluded that the temperature and relative humidity control system is efficient in its energy consumption regarding its operation. It is recommended to incorporate artificial vision methods to identify the materials that are analyzed and thus determine temperature levels in the quality control process. | es_ES |
dc.language.iso | spa | es_ES |
dc.publisher | Escuela Superior Politécnica de Chimborazo | es_ES |
dc.relation.ispartofseries | UDCTFIYE;108T0437 | - |
dc.rights | info:eu-repo/semantics/openAccess | es_ES |
dc.subject | SISTEMA ELECTRÓNICO | es_ES |
dc.subject | SISTEMA ELÉCTRICO | es_ES |
dc.subject | AUTOMATIZACIÓN INDUSTRIAL | es_ES |
dc.subject | LÓGICA PROGRAMABLE | es_ES |
dc.subject | TEMPERATURA | es_ES |
dc.subject | HUMEDAD RELATIVA | es_ES |
dc.subject | PANTALLA OLED | es_ES |
dc.title | Control automático de temperatura y humedad relativa del laboratorio de ensayos de ALUVIDGLASS CIA. LTDA. | es_ES |
dc.type | info:eu-repo/semantics/bachelorThesis | es_ES |
dc.contributor.miembrotribunal | Mora Chunllo, Verónica Elizabeth | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-sa/3.0/ec/ | es_ES |
Aparece en las colecciones: | Ingeniero en Electrónica, Control y Redes Industriales; Ingeniero/a en Electrónica y Automatización |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
108T0437.pdf | 4,28 MB | Adobe PDF | Visualizar/Abrir |
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons