dc.identifier.citation | Bautista Guamán, Jonathan Medardo. (2021). Estudio comparativo de la red de control RS-485 con la red de control ethernet para un sistema de envasado de líquidos en el laboratorio de automatización de la FIE-ESPOCH. Escuela Superior Politécnica de Chimborazo. Riobamba. | es_ES |
dc.identifier.uri | http://dspace.espoch.edu.ec/handle/123456789/21250 | - |
dc.description | El objetivo del presente trabajo de titulación fue comparar la red de control RS-485 con la red de control Ethernet para un sistema de envasado de líquidos en el laboratorio de automatización de la FIE-ESPOCH. Para el proceso de comunicación 485 se utilizó un bloque de distribución Modbus o Splitter permitiendo la comunicación en un solo bus de campo entre los módulos, cables para comunicación 485, dos Controladores Lógicos Programables (PLC) y para la comunicación Ethernet se utilizó un switch, cable de par trenzado sin blindaje (UTP) y conectores RJ45. El sistema de envasado de líquidos consta de cinco estaciones, pero con la metodología SCRUM se seleccionó dos para realizar las comunicaciones 485 y Ethernet para su posterior toma de datos. Las estaciones representadas corresponden a Dosificado (Maestro) y Mezclado (Esclavo). La secuencia de operación inicia cuando la estación de Dosificado le envía un mensaje a la estación de mezclado para correr el programa y activar las válvulas de los líquidos, mezclarlos y si el tanque de la estación maestro está vacío enviar el líquido a través de la activación de la bomba de agua del esclavo. Las estaciones cuentan con sensores de nivel máximo y mínimo para controlar el vaciado y llenado de los recipientes. Adicionalmente se instaló y programó una interfaz hombre máquina (HMI) misma que siempre se encuentra monitoreando cada paso del proceso. En conclusión, la red de control RS-485 permitió la comunicación de las estaciones de una manera más rápida versus la red de control Ethernet por la forma de llevar el dato los Controladores Lógicos Programables (PLCs) bajo el modelo de la Organización Internacional de Normalización (OSI). Se recomienda desarrollar más proyectos añadiendo más dispositivos esclavos a la red de comunicación de tal forma que se puede explorar a profundad su estructura y aplicaciones. | es_ES |
dc.description.abstract | The objective of the present graduation work was to compare the RS-485 control network with the Ethernet control for a liquid packaging system in the automation laboratory of the FIEESPOCH. A Modbus o Splitter distribution block was used for the 485-communication process, allowing communication in a single fieldbus between modules, cables for 485 communication, two Programmable Logic Controllers (PLC) and for Ethernet communication it was used a switch, unshielded twisted pair cable (UTP) and RJ45 connectors. The liquid packaging system consists of five stations, but with the SCRUM methodology, two were selected to carry out 485 communications and Ethernet for later data collection. The stations represented correspond to Dosed (Master) and Mixed (Slave). The operation sequence starts when the Dosing station sends a message to the station of mixing to run the program and activate the valves of the liquids, mix them and if the tank of the master station is empty send the liquid through the activation of the water pump of the slave. The stations have maximum and minimum level sensors to control the emptying and filling of containers. Additionally, a human- machine interface (HMI) was installed and programmed, which is always monitoring each step of the process. In conclusion, the RS-485 control network allowed a faster communication between the stations versus the Ethernet control network due to the way the Programmable Logic Controllers (PLCs) carry the data under the model of the International Standardization Organization (ISO). It is recommended to develop more projects by adding more slave devices to the network of communication in such a way that its structure and applications can be explored in depth. | es_ES |
dc.language.iso | spa | es_ES |
dc.publisher | Escuela Superior Politécnica de Chimborazo | es_ES |
dc.relation.ispartofseries | UDCTFIYE;108T0404 | - |
dc.rights | info:eu-repo/semantics/openAccess | es_ES |
dc.subject | PROTOCOLO DE COMUNICACIÓN | es_ES |
dc.subject | PROCESO DE DOSIFICACIÓN | es_ES |
dc.subject | PROCESO DE MEZCLADO | es_ES |
dc.subject | CONTROLADOR LÓGICO PROGRAMABLE | es_ES |
dc.subject | INTERFAZ HOMBRE MÁQUINA | es_ES |
dc.subject | ORGANIZACIÓN INTERNACIONAL DE NORMALIZACIÓN | es_ES |
dc.title | Estudio comparativo de la red de control RS-485 con la red de control ethernet para un sistema de envasado de líquidos en el laboratorio de automatización de la FIE-ESPOCH. | es_ES |
dc.type | info:eu-repo/semantics/bachelorThesis | es_ES |
dc.contributor.miembrotribunal | Altamirano Santillán, Edwin Vinicio | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-sa/3.0/ec/ | es_ES |
Aparece en las colecciones: | Ingeniero en Electrónica, Control y Redes Industriales; Ingeniero/a en Electrónica y Automatización |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
108T0404.pdf | 9,54 MB | Adobe PDF | Visualizar/Abrir |
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons