dc.identifier.citationParra Llerena, Estefany Mishell. (2023). Diseño e implementación de un biosensor basado en un resonador de anillo para la medición de soluciones de glucosa a distintas concentraciones. Escuela Superior Politécnica de Chimborazo. Riobamba.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/20938-
dc.descriptionEl presente trabajo de titulación tuvo como objetivo diseñar e implementar un biosensor basado en un resonador de anillo para la para la medición de soluciones de glucosa a distintas concentraciones. Para ello se estudió las principales características de los biosensores y de los resonadores de anillo, como también se investigó las principales características del analizador de redes vectoriales (VNA). Se utilizó un material RT/Duroid para la implementación del biosensor, ya que este fue el más óptimo para la implementación del mismo. Una vez implementado el biosensor se prepararon las soluciones de glucosa, sacarosa y sal a diferentes concentraciones para evaluar el funcionamiento y sensibilidad del biosensor. Se utilizó el analizador de redes vectoriales (VNA) para tomar las medidas de amplitud al momento de colocar las diferentes soluciones sobre el biosensor, se tomó el coeficiente de transmisión S21 para poder analizar los datos y ver su variación en amplitud de acuerdo a las concentraciones colocadas sobre el biosensor. Por último, se realizó pruebas con muestras de sangre para compararlas con las concentraciones de glucosa y ver su comportamiento para poder encontrar una similitud entre las variaciones de amplitud de la sangre y las variaciones de amplitud de las concentraciones de glucosa. Se puede decir que al comparar las diferentes concentraciones tanto de glucosa, sal, sacarosa, y la sangre se observó un cambio en el comportamiento del biosensor por lo que se puede decir que es capaz de captar cambios en sus amplitudes de acuerdo a las concentraciones que se coloque dándonos su comportamiento con estas concentraciones.es_ES
dc.description.abstractThis thesis aimed to design and implement a biosensor based on a ring resonator for the measurement of glucose solutions at different concentrations. The study involved investigating the key characteristics of biosensors and ring resonators, as well as exploring the main features of the Vector Network Analyzer (VNA). Due to its optimal properties, an RT/Duroid material was chosen for the biosensor implementation. Once the biosensor was implemented, glucose, sucrose, and salt solutions were prepared at various concentrations to assess the biosensor's functionality and sensitivity. The Vector Network Analyzer (VNA) was employed to measure the amplitude when different solutions were placed on the biosensor. The transmission coefficient S21 was used for data analysis, revealing amplitude variations corresponding to the concentrations applied to the biosensor. Subsequently, blood samples were tested and compared with glucose concentrations to observe similarities in amplitude variations between blood and glucose concentrations. Changes in the biosensor's behavior were observed by comparing different concentrations of glucose, salt, sucrose, and blood. Therefore, it can be concluded that the biosensor can detect changes in amplitudes corresponding to the applied concentrations, indicating its responsiveness to these concentrations.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDCTFIYE;98T00412-
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.subjectBIOSENSORes_ES
dc.subjectRESONADOR DE ANILLOes_ES
dc.subjectANALIZADOR DE REDES VECTORIALESes_ES
dc.subjectGLUCOSAes_ES
dc.subjectRT/DUROIDes_ES
dc.titleDiseño e implementación de un biosensor basado en un resonador de anillo para la medición de soluciones de glucosa a distintas concentraciones.es_ES
dc.typeinfo:eu-repo/semantics/bachelorThesises_ES
dc.contributor.miembrotribunalVeloz Cherrez, Diego Fernando-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/3.0/ec/es_ES
Aparece en las colecciones: Ingeniero en Electrónica, Telecomunicaciones y Redes; Ingeniero/a en Telecomunicaciones

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
98T00412.pdf1,88 MBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons