dc.identifier.citation | Patiño Quihuire, Stalin Daniel. (2022). Implementación de un manual de control de calidad en el área de radiodiagnóstico e intervencionismo del Hospital Padre Carollo un Canto a la Vida. Escuela Superior Politécnica de Chimborazo. Riobamba | es_ES |
dc.identifier.uri | http://dspace.espoch.edu.ec/handle/123456789/19304 | - |
dc.description | El presente Trabajo Experimental estableció como objetivo la implementación de un manual de control de calidad en el área de radiodiagnóstico e intervencionismo del Hospital Padre Carolo Un Canto a La Vida. El procedimiento se basó en el Anexo III del Manual de control de Calidad para Radiodiagnóstico y Radiología Intervencionista, propuesto Subsecretaria de Control y Aplicaciones Nucleares (SCAN), del cual se optó por realizar tres pruebas, consideradas como pruebas mínimas para justificar la elaboración de este trabajo de titulación, entre las que se encuentran: Monitoreo de la tasa de dosis ambiental, inspección de las instalaciones y capacitación al personal ocupacionalmente expuesto (POE). Se identificaron los puntos críticos de cada sala, las salas colindantes y el tipo área; todos estos según la clasificación descrita en el Anexo III. Para la determinación de la tasa de dosis anual se utilizó el valor más alto obtenido en las mediciones, además del factor de uso, factor de ocupación y carga de trabajo semanal; para la inspección de las instalaciones, se consideró la revisión del equipamiento, la estabilidad de los equipos y la verificación de rigidez mecánica de cada uno de ellos. Por último, se consideró la capacitación en temas de protección radiológica, exposiciones no justificadas e identificación de la señalética. Concluyendo con esto que los límites de radiación medidos en las salas se encuentran todos bajo los límites permitidos, la inspección determino el estado óptimo de los equipos y la capacitación se realizó con éxito. Se recomienda la elaboración y la aplicación de un manual de control de calidad, dentro de una institución médica permite identificar, corregir y mejorar los servicios y protocolos de atención a pacientes. | es_ES |
dc.description.abstract | The objective of this experimental work was the implementation of a quality control manual in the radiodiagnostic and interventional radiology area of the Hospital Padre Carollo “Un canto a la Vida”. the procedure was based on annex III of the quality control manual for radiodiagnosis and interventional radiology, proposed by the under- secretariat for nuclear control and applications (SCAN), from which 3 tests were chosen, considered as minimum tests to justify the elaboration of this degree work, among which are: monitoring of the environmental dose rate, inspection of the facilities and training of occupationally exposed personnel (POE). The critical points of each room, the adjoining rooms and the type of area were identified, all according to the classification described in Annex III. For the determination of the annual dose rate, the highest value obtained in the measurements was used, in addition to the Use factor, occupancy factor and weekly workload, for the inspection of the facilities. Finally, training on radiological protection issues, unjustified exposures and identification of signage were considered, concluding that the radiation limits measured in the rooms were all within the permitted limits, the inspection determined the optimal state of the equipment, and the training was successful. It is recommended that a quality control manual be developed and implemented within a medical institution to identify, correct, and improve patient care services and protocols. | es_ES |
dc.language.iso | spa | es_ES |
dc.publisher | Escuela Superior Politécnica de Chimborazo | es_ES |
dc.relation.ispartofseries | UDCTFC;86T00165 | - |
dc.rights | info:eu-repo/semantics/openAccess | es_ES |
dc.subject | RADIACIÓN IONIZANTE | es_ES |
dc.subject | RADIOPROTECCIÓN | es_ES |
dc.subject | PERSONAL OCUPACIONALMENTE EXPUESTO (POE) | es_ES |
dc.subject | EFECTOS BIOLÓGICOS | es_ES |
dc.subject | CONTROL DE CALIDAD | es_ES |
dc.title | Implementación de un manual de control de calidad en el área de radiodiagnóstico e intervencionismo del Hospital Padre Carollo un Canto a la Vida | es_ES |
dc.type | info:eu-repo/semantics/bachelorThesis | es_ES |
dc.contributor.miembrotribunal | Pachacama Choca, Richard Willians | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-sa/3.0/ec/ | es_ES |
Aparece en las colecciones: | Biofísica |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
86T00165.pdf | 3,2 MB | Adobe PDF | Visualizar/Abrir |
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons