Por favor, use este identificador para citar o enlazar este ítem:
http://dspace.espoch.edu.ec/handle/123456789/11569
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.advisor | Nuela Sevilla, Stalin Eduardo | - |
dc.contributor.author | Guaylla López, Jonatan Fabricio | - |
dc.date.accessioned | 2019-08-07T16:35:09Z | - |
dc.date.available | 2019-08-07T16:35:09Z | - |
dc.date.issued | 2019-06-21 | - |
dc.identifier.citation | Guaylla López, Jonatan Fabricio. (2019). Determinación del estado técnico de las tuberías de los tanques de almacenamiento de agua potable del GAD parroquial rural de Licán mediante ultrasonido. Escuela Superior Politécnica de Chimborazo. Riobamba. | es_ES |
dc.identifier.uri | http://dspace.espoch.edu.ec/handle/123456789/11569 | - |
dc.description | Se realizó la determinación del estado técnico de las tuberías de los tanques de almacenamiento de agua potable del GAD parroquial rural de Licán mediante ultrasonido. Para desarrollar este trabajo de titulación se investigó sobre la medición de espesores por medio de técnicas de ensayos no destructivos con ultrasonido, utilizando las normas ASTM E797 guía práctica para la medición de espesores con ultrasonido, la norma AWWA C 150 para el diseño de espesor requerido en las tuberías de agua, y la API 570 para el desgaste que ocurre en las tuberías a través de los procedimientos para la inspección y evaluación del estado de las tuberías que son sometidas al ensayo de ultrasonido a través de la medición de espesores, permitiendo calcular la velocidad de desgaste y vida útil. Para la medición de espesores se utilizó el equipo Benetech GM130 de 5MHz. En el desarrollo se elaboró la codificación y fichas técnicas de los tanques de almacenamiento, luego se realizó la toma de espesores en las tuberías de entrada, salida y desfogue de acero galvanizado, con lo cual se hizo un análisis estadístico y técnico, que ayudará a determinar los espesores máximos, medios, mínimos, y puntos bajos en las zonas ABCD de la sección transversal de las tuberías. Una vez analizado los datos obtenidos de la medición de espesores, se encontró que en la parte superior de la tubería (punto A) se tiene el mayor desgaste, con lo cual se analizó que la pérdida de material debido al deterioro, es de tipo mecánico – corrosivo, además se calculó la velocidad de desgaste, vida útil y las próximas inspecciones en las tuberías para finalizar con la elaboración de los reportes finales de inspección en los 9 tanques de almacenamiento. Se recomienda realizar un análisis a las tuberías con menor vida útil, en base a la velocidad de desgaste para la planificación de tareas de mantenimiento y tomar como base este trabajo para el análisis de sistemas similares con tuberías de acero galvanizado en otros sectores de la provincia. | es_ES |
dc.description.abstract | The determination of the technical state of the conducts of the drinking water storage tanks of the rural parish GAD Licán was carried out by means of ultrasound. To develop this investigative work was investigate on thickness measurement by means of ultrasound non-destructive testing techniques, used the ASTME797 standards, practical guide for measuring thicknesses with ultrasound the AWWA C 150 standard for the design of thicknesses required in water pipes, conventional water, and the API 570 for wear that occurs in the pipes through the procedures for the inspection and evaluation of the condition of the pipes that are subjected to the ultrasound test through the measurement of thicknesses, allowing to calculate the speed of wear and useful life. To measure the thickness, Benetech GM130 5MHz equipment was used. In the development, the coding and the technical data sheets of the storage tanks were elaborated, then the thickness was taken in the entrance, exit and exhaust connections of galvanized steel, with which performed a statistical analysis and technical, that a determine thickness the maximum, average, minimum and low points in the ABCD areas of the cross section of the pipes. once the data obtained from the measurement of thicknesses have been analyzed, it was found that at the top of the pipe (point A) you have the greatest wear, which has analyzed the loss of material due to deterioration, is mechanical - corrosive type, in addition, the wear speed was calculated, the service life and the next inspections in the pipes were to finalize with the elaboration of the final inspection reports in the 9 storage tanks. It is recommended to perform an analysis of the pipes with less useful life, based on the wear rate for the planning of maintenance tasks and to take as a basis this work for the analysis of similar systems with galvanized steel pipes in others sectors of the province. | es_ES |
dc.language.iso | spa | es_ES |
dc.publisher | Escuela Superior Politécnica de Chimborazo | es_ES |
dc.relation.ispartofseries | UDCTFM;25T00355 | - |
dc.rights | info:eu-repo/semantics/openAccess | es_ES |
dc.subject | TECNOLOGÍA Y CIENCIAS DE LA INGENIERÍA | es_ES |
dc.subject | ULTRASONIDO | es_ES |
dc.subject | TANQUES DE ALMACENAMIENTO | es_ES |
dc.subject | TUBERÍAS DE ACERO GALVANIZADO | es_ES |
dc.subject | MEDICIÓN DE ESPESORES | es_ES |
dc.subject | VELOCIDAD DE DESGASTE | es_ES |
dc.subject | VIDA ÚTIL | es_ES |
dc.title | Determinación del estado técnico de las tuberías de los tanques de almacenamiento de agua potable del GAD parroquial rural de Licán mediante ultrasonido. | es_ES |
dc.type | bachelorThesis | es_ES |
dc.contributor.miembrotribunal | Calderón Freire, Edisson Fernando | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-sa/3.0/ec/ | es_ES |
Aparece en las colecciones: | Ingeniero de Mantenimiento; Ingeniero/a en Mantenimiento Industrial |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
25T00355.pdf | 1,92 MB | Adobe PDF | Visualizar/Abrir |
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons